FZB Fluoroplastic Self-priming Pump

FSB is Wolong’s independent R&D product, especially for low sump application, pump installed above the sump and tank. Easy for operating and maintain servicing. Patent Number: ZL200820038727.9

INQUIRY  
  • Application
  • Design Feature
  • Model and Parameter
  • Material of Construction
  • Installation Drawing
  • Performance curve

Medium
●Acids & lyes
●Waste water
●Chlorine water
●Electrolyte
Application
●Chemical industry
●Pesticide
●Acid and alkali making
●Papermaking
●Acid pickle process
●ElectronicsIndustry

Range of application
1.Pressure Limitation:<1.0MPa
2.Temperature:
   Temperature range:-20°C ~ 80°C
   Ambient temperature:0~ 40°C
   Ambient humidity:35~85%RH
3. In general, slurries should not be handled; liquid maximum practical and crystal content not more than 10%, pump not allowed to transfer a mass of bubbles However.
4. The viscosity of medium influence the performance of the pump: when the viscosity changed, the pump performance change also.

-Patent product, base on IHF centrifugal pump structure, installed the double volute self-priming pump casing on IHF pump, simple structure and for widely usage.  

-Corrosion and pressure resistance, wet parts are made of corrosion resistant fluoroplastic, with these advantages, FZB pumps available to high corrosive applications. Pump base plate is made of metal; make the pump available to high pressure resistance applications.  

-Easy for operating
Developed for low sump application, pump installed above the sump or tank, which easy for operating, maintenance and repair.

Specification


Model and parameter

ItemModelFlow
 (m3/h)
Head
 (m)
Efficiency
 (%)
NPSHa
 (m)
Inlet x outlet (mm)Self-priming height ( m)Self-priming time
 ( seconds)
Speed z
 (RPM)
Power
 (KW)
Pump and motor weight
 (kg)
140FZB-20522353.0040x50118029003160
*82042
121740
250FZB-20822353.0050x50118029003160
*122042
151740

Remark:
-item marked with”*”for standard parameter
-Please choose similar or same parameter pump, if the parameter is not in the range of this table, we could improve it according to on site application.  
-If flow rate is too small, the outlets add backflow connection.
-Motor phase: 2 phase
-If liquid specific gravity is more than 1.3g/cm3, the motor power should be added.
-If liquid with HF acid or some other type special liquid, spare parts material will be changed according to liquid.
-Self priming height= 3m@water liquid/liquid density

SerialModelExterior and installation dimensionInlet flange dimensionOutlet flange dimension
LSPfWTHhh1xkijmn-Ødegnn-Øt
Short bracket40FZB-205903101601102201703051402406512401001304-Ø13501001304-Ø13
50FZB-205903101601102201703051402406512401001304-Ø13501001304-Ø13

Contact Us